Customization: | Available |
---|---|
After-sales Service: | Video Conversation Guidance |
Warranty: | 18 Months From Production |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Silent Operation: Masterfully engineered for ultra-quiet performance, this premium horizontal water pump is the epitome of noise-free engineering. Professional buyers cherish pumps that function with serene discretion, ensuring an undisturbed environment that seamlessly integrates into daily life, free from noise pollution.
Low Power Consumption: Expertly designed for minimal power consumption, this innovative pump significantly cuts down on energy costs while decreasing its environmental footprint. Discerning buyers are drawn to pumps that excel in energy efficiency, providing a solution that is both economically wise and ecologically responsible.
Horizontal Design: Elegantly crafted with a thoughtful horizontal design, this pump ensures effortless installation and maintenance. Buyers are impressed by its space-efficient structure and ease of access, making it the perfect choice for applications where space is a premium.
Variable Frequency Control: This advanced pump, featuring variable frequency control, empowers users with precise modulation of water flow and pressure. Buyers highly value this adaptability, allowing them to customize the pump's performance to meet specific requirements, thereby optimizing water usage efficiently.
Meet the High Efficiency Horizontal Water Pump, a state-of-the-art solution designed to meet the diverse needs of modern households. This pump combines the reliability of high-performance water systems with the added benefits of low noise operation and horizontal installation, appealing to professional buyers across the globe.
Efficiency is the cornerstone of this pump's design. With a superior hydraulic performance, it delivers maximum water flow and pressure while consuming minimal energy. This feature is highly valued by professional buyers in the energy-efficient sector, as it contributes to reduced energy bills and a smaller carbon footprint.
The pump's horizontal installation design offers unparalleled flexibility. It allows for easy integration into existing water systems, minimizing installation time and costs. This aspect is particularly appealing to professional buyers in the construction and plumbing industries, who require versatile and adaptable solutions.
Low noise operation is another key selling point. The pump operates at sound levels below 40 dB, ensuring that it doesn't disturb the peace and quiet of your home. This feature is highly appreciated by professional buyers in the interior design and real estate sectors, as it enhances the overall living experience.
Durability and reliability are hallmarks of this water pump. Constructed from high-quality materials, it is designed to withstand the rigors of daily use and provide long-lasting performance. The pump's sealed design prevents leaks and corrosion, ensuring worry-free operation for years to come.
In summary, the High Efficiency Horizontal Water Pump offers a perfect blend of efficiency, flexibility, and low noise operation. Its appealing features have made it a favorite among professional buyers who demand the best in terms of performance, quality, and sustainability. With its versatile design and reliable performance, this pump is poised to become a staple in modern household water systems
.Type | Motor (kW) |
Q(m³/h) | 0.5 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 |
CHL2-20 | 0.37 | H (m) |
19 | 18 | 16.5 | 15 | 13 | 10 | 7.5 |
CHL2-30 | 0.37 | 28 | 26.5 | 24.5 | 22 | 19 | 15.5 | 12 | |
CHL2-40 | 0.55 | 36 | 34.5 | 33 | 29 | 25 | 20.5 | 16 | |
CHL2-50 | 0.55 | 45.5 | 43 | 40 | 36 | 31.5 | 26.5 | 20.5 | |
CHL2-60 | 0.75 | 53.5 | 51 | 48 | 44 | 39 | 32 | 24 |
Type | Motor (kW) |
Q(m³/h) | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
CHL4-20 | 0.37 | H (m) |
19 | 18 | 17 | 15 | 12.5 | 10 | 8 |
CHL4-30 | 0.55 | 28 | 27 | 26 | 23.5 | 20.5 | 17 | 13 | |
CHL4-40 | 0.75 | 37.5 | 36 | 34 | 31 | 27 | 23 | 19 |
Type | Motor (kW) |
Q(m³/h) | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
CHL8-10 | 0.75 | H (m) |
10 | 9.5 | 9.3 | 9 | 8 | 7.5 | 7 |
CHL8-20 | 0.75 | 20 | 19.5 | 19 | 18 | 17 | 15.5 | 14 | |
CHL8-30 | 1.1 | 29.5 | 29 | 28 | 27 | 25 | 23 | 21 | |
CHL8-40 | 1.5 | 39 | 38 | 37 | 35 | 33 | 30.5 | 27.5 | |
CHL8-50 | 2.2 | 51 | 49.5 | 47.5 | 45 | 42.5 | 39.5 | 36 |
Type | Motor (kW) |
Q(m³/h) | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
CHL12-10 | 0.75 | H (m) |
11.5 | 11.2 | 11 | 10.5 | 10 | 9.5 | 9 | 8 | 7 | 6 |
CHL12-20 | 1.2 | 23 | 22.5 | 22 | 21.5 | 20.5 | 19.5 | 18.5 | 17 | 15.5 | 13 | |
CHL12-30 | 1.8 | 35 | 34.5 | 33.5 | 32.5 | 31 | 29.5 | 28 | 26 | 23.5 | 20 | |
CHL12-40 | 2.4 | 47 | 46 | 45 | 43.5 | 41.5 | 39.5 | 37.5 | 35 | 31.5 | 27.5 | |
CHL12-50 | 3 | 60 | 58 | 56.5 | 55 | 52.5 | 50 | 47 | 44 | 40 | 35 |
Type | Motor (kW) |
Q(m³/h) | 8 | 10 | 12 | 14 | 15 | 16 | 18 | 20 | 22 |
CHL15-10 | 1.1 | H (m) |
12 | 11 | 10.5 | 9.5 | 9 | 8.5 | 7.5 | 6.5 | 6 |
CHL15-20 | 2.2 | 24.5 | 24 | 23 | 22 | 21 | 20.5 | 19 | 18 | 16 | |
CHL15-30 | 3 | 38 | 37 | 35.5 | 34 | 33 | 32 | 30 | 28 | 25 |
Type | Motor (kW) |
Q(m³/h) | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 |
CHL20-10 | 1.1 | H (m) |
13.5 | 13 | 12.5 | 12 | 11 | 10 | 9 | 8 | 7 | 6 |
CHL20-20 | 2.2 | 27 | 26.5 | 25.5 | 25 | 23.5 | 22 | 20.5 | 18.5 | 17 | 14.5 | |
CHL20-30 | 4 | 39.5 | 39 | 38 | 37.5 | 35.5 | 34 | 31.5 | 29 | 26 | 23 |
Model | Driving motor | Q (m³/h) |
0.5 | 1 | 1.5 | 2 | 2.5 | 3 | 3.5 | |
(kW) | (hp) | |||||||||
CHLF(T)2-20 | 0.37 | 0.5 | H (m) |
19 | 18 | 16.5 | 15 | 13 | 10 | 7.5 |
CHLF(T)2-30 | 0.55 | 0.75 | 28 | 26.5 | 24.5 | 22 | 19 | 15.5 | 12 | |
CHLF(T)2-40 | 0.55 | 0.75 | 36 | 34.5 | 33 | 29 | 25 | 20.5 | 16 | |
CHLF(T)2-50 | 0.55 | 0.75 | 45.5 | 43 | 40 | 36 | 31.5 | 26.5 | 20.5 | |
CHLF(T)2-60 | 0.75 | 1 | 53.5 | 51 | 48 | 44 | 39 | 32 | 24 |
Model | Driving motor | Q (m³/h) |
1 | 2 | 3 | 4 | 5 | 6 | 7 | |
(kW) | (hp) | |||||||||
CHLF(T)4-20 | 0.55 | 0.75 | H (m) |
19 | 18 | 17 | 15 | 12.5 | 10 | 8 |
CHLF(T)4-30 | 0.55 | 0.75 | 28 | 27 | 26 | 23.5 | 20.5 | 1 | 13 | |
CHLF(T)4-40 | 0.75 | 1 | 37.5 | 36 | 34 | 31 | 27 | 23 | 19 | |
CHLF(T)4-50 | 1.1 | 1.5 | 47 | 45 | 42.5 | 39 | 34 | 29 | 23 | |
CHLF(T)4-60 | 1.1 | 1.5 | 56 | 54 | 51 | 47 | 41.5 | 35.5 | 28 |
Model | Driving motor | Q (m³/h) |
5 | 6 | 7 | 8 | 9 | 10 | 11 | |
(kW) | (hp) | |||||||||
CHLF(T)8-10 | 0.75 | 1 | H (m) |
10 | 9.5 | 9.3 | 9 | 8 | 7.5 | 7 |
CHLF(T)8-20 | 0.75 | 1 | 20 | 19.5 | 19 | 18 | 17 | 15.5 | 14 | |
CHLF(T)8-30 | 1.1 | 1.5 | 29.5 | 29 | 28 | 27 | 25 | 23 | 21 | |
CHLF(T)8-40 | 1.5 | 2 | 39 | 38 | 37 | 35 | 33 | 30.5 | 27.5 | |
CHLF(T)8-50 | 2.2 | 3 | 51 | 49.5 | 47.5 | 45 | 42.5 | 39.5 | 36 |
Model | Driving motor | Q (m³/h) |
7 | 8 | 9 | 10 | 12 | 13 | 14 | 15 | 16 | ||
(kW) | (hp) | ||||||||||||
CHLF(T)12-10 | 0.75 | 1 | H (m) |
11.5 | 11.2 | 11 | 10.5 | 10 | 9.5 | 9 | 8 | 7 | 6 |
CHLF(T)12-20 | 1.2 | 1.6 | 23 | 22.5 | 22 | 21.5 | 20.5 | 19.5 | 18.5 | 17 | 15.5 | 13 | |
CHLF(T)12-30 | 1.8 | 2.4 | 35 | 34.5 | 33.5 | 32.5 | 31 | 29.5 | 28 | 26 | 23.5 | 20 | |
CHLF(T)12-40 | 2.4 | 3.3 | 47 | 46 | 45 | 43.5 | 41.5 | 39.5 | 37.5 | 35 | 31.5 | 27.5 | |
CHLF(T)12-50 | 3 | 4 | 60 | 58 | 56.5 | 55 | 52.5 | 50 | 47 | 44 | 40 | 35 |
Model | Driving motor | Q (m³/h) |
8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | |
(kW) | (hp) | ||||||||||
CHLF(T)16-10 | 1.1 | 1.5 | H (m) |
12.8 | 12.5 | 12 | 11.5 | 10.5 | 9.5 | 8 | 7 |
CHLF(T)16-20 | 2.2 | 3 | 26 | 25 | 24 | 23 | 21.7 | 20 | 18 | 15.5 | |
CHLF(T)16-30 | 3 | 4 | 40 | 39 | 38 | 36 | 34 | 31.5 | 29 | 25 | |
CHLF(T)16-40 | 4 | 5.5 | 53.5 | 52 | 50 | 48 | 45 | 42 | 38 | 33.5 |
Model | Driving motor | Q (m³/h) |
10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | |
(kW) | (hp) | ||||||||||||
CHLF(T)20-10 | 1.1 | 1.5 | H (m) |
13.5 | 13 | 12.5 | 12 | 11 | 10 | 9 | 8 | 7 | 6 |
CHLF(T)20-20 | 2.2 | 3 | 27 | 26.5 | 25.5 | 25 | 23.5 | 22 | 20.5 | 18.5 | 17 | 14.5 | |
CHLF(T)20-30 | 4 | 5.5 | 39.5 | 39 | 38 | 37.5 | 35.5 | 34 | 31.5 | 29 | 26 | 23 | |
CHLF(T)20-40 | 4.4 | 6 | 53 | 52 | 51 | 50 | 48.5 | 46.5 | 43 | 40 | 36 | 32.5 |
Q: What is the delivery time?
A:The sample can be sent to customer within 7-10 days.
The batch order can be shipped within 20 days after receiving deposit payment
Q:Where is your loading port?
A: Shanghai port, China
Q: Is it all right to make customer's own brand name?
A: Can make OEM if order quantity reached 200pcs totally
Q: What is your payment term?
A: 30% in advance, 70% balance the B/L or T/T
Q: What Hz are the parameters given in the picture and text for?
A: 50HZ, if 60GZ is required, we will provide new parameters or send the requirements via email, and we will send the 60HZ parameter data to your location.
Q: What is the warranty of the product?
A: We offer 1 year product life guarantee and a generous 1 year warranty on all purchases that begin with the BL
Q: What information shall I provide you when I need your offer?
A: Normally, we need customer to supply the pump flow, total head, pump material (copper wire or aluminum wire? Stator length), voltage, frequency, etc, so we can quote exactly what customer need
Q: Can you accept customized products?
A: Yes we accept your specific order if you could provide us with your requirements.
Q: Is there any leakage problem of this pump?
A: We test 100% and long time for the pump, to make sure there is no leakage problem.
Q: Do you supply sample?
A: We can supply sample, but customer have to pay for the sample fee
Q: What is the delivery time?
A:7-10 after we receiving your deposit.
Q: Where did you export to?
A: We export to more than 50 countries, for example, Israel, South Africa, Germany, Poland, Spain, Vietnam, Malaysia, Russia, Thailand, Mexico, Brazil, Chile, etc.
Q: Can you recommend some pumps according to the working conditions?
A: We have been working as sales engineers for more than 15 years. It can be provided according to some data we need.
Q: Can you provide guidance on after-sales issues and installation problems?
A: Our after-sales engineers are professionals who have been working for more than 10 years, and we will provide free video guidance to customers who purchase our products.